KYN28A-12 High-voltage Medium-mounted Withdrawable Switchgear

The KYN28-12kV is an indoor AC metal-clad withdrawable switchgear designed for three-phase power systems with a rated voltage of 12kV and frequency of 50/60Hz.

Product Display

The KYN28-12kV is an indoor AC metal-clad withdrawable switchgear designed for three-phase power systems with a rated voltage of 12kV and frequency of 50/60Hz. It serves as a critical component for receiving, distributing, and managing electrical power in the following applications:

  • Power plants
  • Substations
  • Industrial and mining facilities
  • High-rise buildings

Core Functions:

  1. Power Control: Enables efficient switching and load management.
  2. Protection: Safeguards circuits against overloads, short circuits, and faults.
  3. Monitoring: Supports real-time electrical parameter detection (e.g., current, voltage).

 

Product Specification

ParameterUnitTechnical Parameter
Rated VoltageKV12
Rated Insulation LevelPower Frequency Withstand Voltage (1min): Phase-to-earth / Isolated poleKV42/48
Lightning Impulse Withstand Voltage: Phase-to-earth / Isolated poleKV75/85
Rated FrequencyHZ50
Rated CurrentA630~3150
Main Busbar Rated CurrentA1250,1600,2000,2500,3150,4000
Branch Busbar Rated CurrentA630,1250,1600,2000,2500,3150,4000
Rated Short-time Withstand Current (4s)KA16,20,25,31.5,40,50
Rated Peak Withstand Current ※KA40,50,63,80,100,125
Ingress Protection (IP) RatingEnclosure Protection: IP4X (closed); IP2X (with circuit breaker door open)
Dimensions (Width × Depth × Height)mm800(1000)X1300(1500)X2000※※
WeightKg800~1200

Operating Environmental Conditions

  1. Ambient Air Temperature:
    • Upper limit+40℃
    • Lower limit-10℃
  2. Relative Humidity:
    • Daily average: ≤ 95%
    • Monthly average: ≤ 90%
  3. Altitude:
    • Shall not exceed 1000 meters above sea level (m.a.s.l.).
  4. Seismic Conditions:
    • Seismic intensity shall not exceed Level 8 (per GB/T 17742 Chinese Seismic Intensity Scale).
  5. Site Conditions:
    • Installation area must be free from:
      • Fire or explosion hazards
      • Severe contamination
      • Chemical corrosion
      • Excessive vibration

*When the conditions of use exceed the above scope, the user and the manufacturer shall negotiate to determine the allowable scope and technical measures.